What we claim, and what we won’t.

What we will claim, what we won’t, and what we’re still measuring. Every external number links to its source. Everything about a Leafyverse home remains unvalidated until the pilot produces it.

The printed wall system

A hybrid structure, always: printed concrete walls on a conventional foundation, under an engineered roof, with standard MEP. The printer gives curves for free and removes a trade; it does not print a finished house.

ICC 1150-2026 is the first national standard for 3D-printed concrete walls — published 28 Mar 2026, ANSI-approved 15 Jul 2026. Leafyverse’s detail library is written to it, not to one machine.
Source: ICC IS-3DACT (opens in a new tab)
Reference wall for the pilot: ICON’s system holds ICC-ES ESR-4652 with a 2-hour fire rating (178 minutes under ASTM E119), Miami-Dade HVHZ approval to 175 mph design wind, and an R-18 assembly.
Source: ICON, Jun 2026 (opens in a new tab)
Where a partner’s wall lacks a report, ICC-ES AC509 defines the testing Leafyverse will commission.
Source: ICC-ES AC509 (opens in a new tab)
NIST’s position: layer bonding, mixes and long-term performance still require testing. That is why the first ten homes use one system and one detail library.
Source: NIST (opens in a new tab)
Printer-agnostic by policy: ICON Titan (deliveries from early 2027), COBOD BOD3, 14Trees Cedar and Alquist’s arm systems are all candidates; Leafyverse owns no printer before year three.
Source: ICON Titan (opens in a new tab)

Where the money goes in a Canopy 01

  1. Printed wall11.9%
  2. Living roof4.7%
  3. Roof structure9.6%
  4. MEP14%
  5. Interiors14.9%
Share of the Canopy 01 target cost. The printed wall is 12% of the home; the living roof, 4.7%.

Carbon: what is true

We will not say greener than wood. The honest position: put concrete where it earns its keep — a hot climate, under a garden, for a century — and report the numbers.

Two independent peer-reviewed life-cycle studies find printed Portland-cement walls carry 54–99% higher embodied carbon than wood framing.
Source: Construction and Building Materials, Sept 2025 (opens in a new tab)
A second study reaches the same direction.
Source: Journal of Building Engineering, Apr 2026 (opens in a new tab)
ICON’s own MIT-co-authored study shows only a 0.5–3% embodied-carbon advantage; its real finding is 9% lower annual operational carbon in Phoenix, the best result of any climate studied, because thermal mass works in hot-dry conditions. That 9% is the hypothesis our pilot will test.
Source: MIT CSHub, Mar 2024 (opens in a new tab)
Cement is about 7% of global CO₂.
Source: GCCA, Nov 2025 (opens in a new tab)
Lower-clinker mixes are specified wherever the partner offers one. ICON’s FormCrete claims 24% lower carbon than its previous mix (company claim).
Source: ICON wall system (opens in a new tab)
Every home ships with a one-page environmental scorecard using EPA embodied-carbon reporting criteria and product EPDs where they exist.
Source: EPA (opens in a new tab)

The living roof, engineered for heat

The roof is 4–5% of cost and the whole brand. It is designed as a garden from day one — structure rated for saturated planting, drip irrigation, a leak-detection layer, a flow meter, and a five-year care contract.

Extensive assemblies weigh 15–30 psf and retain 1–1.5 inches of rain in four inches of media; peak runoff reduced up to 65% and delayed up to three hours; planted roofs last about twice as long as conventional roofs.
Source: GSA (opens in a new tab)
Phoenix roofs use a desert palette, not sedum. ASU’s Tempe Transportation Center test plots used Dalea frutescens, bear grass, deer grass and ice plant on 2–3 gallons per plot per week of drip irrigation.
Source: greenroofs.com — Tempe Transportation Center (opens in a new tab)
Singapore’s guidance puts many extensive systems at 90–150 kg/m² — background context, not a design load.
Source: NParks (opens in a new tab)
Retrofit green roofs do not sell: the District of Columbia ended its residential green-roof rebate in 2023 for lack of uptake. Roofs designed as gardens do.
Source: Ward 1 Sustainability (opens in a new tab)
Ground-level landscape follows Phoenix’s low-water plant list, which the city says cuts outdoor water use 85% versus turf and qualifies for a $2/sq ft turf-removal rebate.
Source: City of Phoenix (opens in a new tab)

The eight layers, top down

  1. Locally selected shallow-root planting
  2. Engineered growing medium (~4 in)
  3. Filter fabric
  4. Drainage / water-retention layer
  5. Protection mat
  6. Root-protection and waterproofing assembly
  7. Positive drainage slope
  8. Engineered roof deck with thermal and air control

What the pilot will measure

  • Plant survival ≥ 90% through one Phoenix summer
  • Irrigation under 0.6 gal / sq ft / week, metered
  • Roof-surface temperature vs. a bare membrane
  • Stormwater retained per event
  • Zero water intrusion over twelve months

Mix chemistry and binder research

In progress

In progress. Leafyverse does not yet publish its own mix-design or binder research. The pilot’s mix will be the partner’s evaluated mix (see the wall system). Low-clinker options (LC3, slag and fly-ash blends, and the partner’s proprietary lower-carbon mixes) are under review for the first homes after the pilot. Findings will be published here with their test data.

Resilience and durability

What a printed wall is good at: fire, wind, termites, rot. These are measured properties of evaluated systems, not promises about a Leafyverse home until ours is tested.

Insurance costs are up 72% since 2019 and 22.7 million renter households are cost-burdened; resilience is an economic argument, not a marketing one.
Source: Harvard JCHS 2026 (opens in a new tab)
Fannie Mae treats traditionally designed printed homes as ordinary site-built housing for lending purposes.
Source: Fannie Mae SEL-2023-08 (opens in a new tab)

We will claim, with measurement

  • Lower operational energy from thermal mass in hot-dry climates — measured
  • Stormwater retention and roof-surface cooling from the living roof — measured
  • Fire and wind ratings of the evaluated wall system — from its report
  • A lower-clinker mix where the partner offers one — named

We will not claim

  • Greener than wood
  • Zero carbon
  • Maintenance-free
  • A house printed in 24 hours
  • Cheaper because printed